Frame/Housing: | Aluminum die-casting | ||||||||||||||||||||
Impeller: | Plastic or steel | ||||||||||||||||||||
Bearing System: | Ball bearing | ||||||||||||||||||||
Motor: | Shaded pole or capacitor start-run | ||||||||||||||||||||
Protection: | Impedance-Protected or Thermally-Protected or Electronically-Protected | ||||||||||||||||||||
Insulation Resistance: | Above 100MΩ, DC500V. | ||||||||||||||||||||
Dielectric withstand voltage | AC 1,500V (50/60Hz) one minute | ||||||||||||||||||||
Life Expectancy: | Ball bearing: Over 40,000 hr. (at 40℃) | ||||||||||||||||||||
Safety Approval: | CUL, CE, TUV, either UL or ETL. | ||||||||||||||||||||
Description of Model No. |
|
UF400AAA23H1C4A | |||
---|---|---|---|
Rated Voltage | 230 V | ||
Frequency | 50 Hz | ||
Input Power | 287 W | ||
Rated Current | 1.26 A | ||
Locked Current | 1.7 A | ||
Speed | 1250 RPM | ||
Maximum Air Flow | 53.8 m3/min. | ||
Maximum Air Flow | 1900 CFM | ||
Maximum Pressure | 49.7 mmH2O | ||
Maximum Pressure | 1.96 InchH2O | ||
Noise | 73 dB | ||
Weights | 5.45 kg |